Base Station/Belt Pack PC Software
Important: Do not attempt to load this latest version 2.6.4 if your existing firmware is earlier than 2017. Example: Firmware BASE170523A, the 17 refers to the year. If your current firmware is 16 or less, please call technical support for further information. Trying to install over year 16 and prior will cause the base and packs to stop operating as an intermediate update is necessary.
Note: Radio Active Designs newest software application: Post 600MHz Auction FCC Compliant, Version 2.6.4 contains updated UV-1G firmware Version BASE190129A and BELT190129A. Once the software application Version 2.6.4 is installed it has the ability to notify you of the latest software & firmware downloads available. Software application Version 2.6.4 has the following changes.

Base Station
UHF 600 MHz band changes for North America. Compliant with new post 600MHz auction FCC guidelines.
470 – 607.975 MHz
614.025 – 615.975 MHz (power limited to 20mW)
653.025 – 662.975 MHz (power limited to 20mW)
Note: 616 – 653 MHz and 663 MHz and up can’t be used.
Belt Pack
UHF 600 MHz band changes for North America. Compliant with new post 600MHz auction FCC guidelines.
470 – 607.975 MHz
614.025 – 615.975 MHz (power limited to 20mW)
653.025 – 662.975 MHz (power limited to 20mW)
Note: 616 – 653 MHz and 663 MHz and up can’t be used
Added microphone audio bandwidth option (Normal/Reduced).
Added re-latching of the transmitter when pilot drops out then comes back.
Technical Support
Please contact technical support for direct assistance.
Monday – Friday
8 am – 6 pm PST
technicalsupport@radioactiverf.com
Phone: 402-477-0695
Software application Version 2.6.4 will NOT work with prior firmware versions for bases and belt packs. We recommend using the latest software application version and installing the latest firmware to ensure the best performance from your UV-1G equipment.
While updating firmware on Body Packs and Base Stations, please disable any file syncing and computer protection software such as Dropbox and Malwarebytes. Disabling them will enable faster and more stable firmware updating times.
Connecting your base station or belt pack to a computer for programming & firmware updating may take a second attempt to complete the USB driver configuration for that device.
Note: RAD Software does not work with Windows XP, support for XP is no longer provided.
Warning: Version 2.6.4 update will limit the tuning range of your UV-1G System to meet the July 13th, 2020 FCC Post 600MHz Specifications. No update is required until July 13th, 2020. Contact technical support with questions or concerns prior to updating your system to Version 2.6.4.